- home > Supply > Shandong supply surface magnetic detectors | shelf surface current flaw detectors leeb610
Information Name: | Shandong supply surface magnetic detectors | shelf surface current flaw detectors leeb610 |
Published: | 2014-06-10 |
Validity: | 30 |
Specifications: | leeb-e610 input voltage ~ 220V ± 10% ,50-60HZ Current DC 1.8A probe pole lifting force from the 20-200mm DC sensitivity than 30Kg Type A specimens show a clear power cable 5.5 m Operating Temperature |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Faribault instrument ★ factory direct phone: 13628326704 QQ: 1739342435 leeb-e610 magnetic detectors of the yoke type magnetic detector is a small portable non-destructive testing of special equipment, is the use of a magnetic field of the workpiece principle designed for small non-destructive testing equipment , has been to explore the work of the cracks show a clear, stable and reliable performance and easy operation and many other features. This instrument uses probes directly wound on a coil, the induced magnetic field, the magnetization of the workpiece. The device has a small size, light weight, large forces and joint activities to enhance adjustable, and suitable for flat welds, fillet welds, pipe, pressure vessels, pipes, shafts and shape complex parts of the testing. Service Hotline: 13628326704. QQ: 1739342435 Faribault leeb-e610 magnetic detector functions and features magnetic detector test piece pictures @ For industry products: oil, shipbuilding, automobiles, coal, machinery, bridges, chemical, railways, standard parts, aircraft manufacturers, engine parts, etc. . @ Applicable flaw: you can detect by forging, hardening, welding, surface and near-surface fatigue caused by defects. @ Random with LED lights, a great convenience for the customer. @ DC power supply for the rechargeable lithium battery, very suitable for field site without power and high voltage unfit containers, pipelines and bridges scene. @ Brightness, long life, easy to replace, is a technological innovation of portable magnetic detectors. @ This product has applied for national patents, protection of national patent laws, with other companies to imitate prohibited. Faribault leeb-e610 magnetic detectors technical parameters leeb-e610 input voltage ~ 220V ± 10% ,50-60HZ Current DC 1.8A probe pole lifting force from the 20-200mm DC sensitivity than 30Kg Type A specimens show a clear power cable 5.5 m Operating temperature -10-50 ° C Working cycle 2 minutes on and 2 minutes off LED lights 3W Instrument Weight 2.9Kg Dimension 190 × 248 × 56mm rechargeable lithium battery Faribault leeb-e610 magnetic detectors standard leeb-e610 standard Configure a yoke-type magnetic detector input power cord sets a magnetic paste an electric pen a box Manual 1 product certification 1 Warranty Card 1 Faribault leeb-e610 magnetic detectors Other Help magnetic detectors? Work Principle accessory power cable is an three-core cable, one end of the probe is inserted through the circular air plug the other end is connected to the AC ~ 220V outlet. Matching probes made of high strength insulating material, after passing inspection fused with epoxy glue, to achieve both sealed insulation, and easily damaged, comfortable operation; has joint activities on the probe, available to users on a specific piece; can be used on both sides of the plane of the yoke, the shape of the workpiece is to look at the specific magnetization. Annex lithium access to the instrument's air plugs, the AC-DC converter switching elected "O", you can begin testing the operation of the DC. Magnetic detectors? Notes 1, the instrument in use, the work load should be avoided to prevent unnecessary rise or damaged. 2, when using the probe, face is detected workpiece to maintain good contact with the press start button switch on the magnetic charge, this time testing the best, the probe should avoid the collision, keep it clean. 3, in use, if you find the probe line package with fever cases, the proper rest and then put into use; If you find serious heat probe line package, you should immediately stop using and check the cause, reconditioned before use, otherwise it will damage the probe . 4, stop using the instrument should cut off the power switch on the switchboard. 5, after the end of the testing, the probe in the active joints, should be cleared of debris and add oil. 6, the use of magnetic suspension agent, should be added to the amount of rust. 7, do not blindly use, not nearly hot objects; do not work in the rain, do not spray the magnetic suspension is sprayed onto the switch, plug socket. 8, such as LED lighting is damaged, you can contact manufacturers maintenance; Users can also buy LED lights from the factory, install it yourself. Magnetic detectors? Steps 1, surface pretreatment remove surface contaminants, such as oil, rust, paint layer, burrs and dirt, oxide and metal scraps. 2, the magnetization and the magnetic powder is applied, the magnetic head must be in close contact with the surface of the medium, while energized, the magnetic side of the spray dry method must be detected at the surface and the powder is completely dry conditions, otherwise the powder will adhere to the surface, so that effects of substrate defects observed variation. Dry detected throughout the magnetization process to remain energized magnetic order only after the removal of the magnetization observed magnetic field marks. When applying powder, dry mist should be homogeneously distributed in the subjects of the workpiece surface. Magnetic detectors? Use and maintenance 1, first connect the power cable and tighten the probe, and then pass ~ 220V AC, the AC-DC converter switching elected "I", you can begin testing the operation of the exchange. 2, the lithium and tighten the connection with the probe, then the AC-DC converter switching elected "O", you can begin testing the operation of the DC. 3, the shape of the workpiece according to the type of probe is to adjust or remove the probe angle joints. 4, before using this flaw, the first contact with the probe was to explore the work is good, being sprayed on the surface of the workpiece probe magnetic or magnetic suspension, then press the magnetization switching on the probe handle, work was magnetized state, Release the buttons, switches, observe whether the workpiece with a magnetic marks, if any crack, a crack in place when the magnetization of magnetic workpiece will coalesce to form a magnetic marks. Appendix: part of the introduction of magnetic paste and use magnetic paste: black powder, wetting agents, dispersing agents, suspending agents, defoamers, rust inhibitors, the instrument is equipped with a magnetic paste easily melt in water, easy to configure, can improve the effectiveness of magnetic particle flaw detection, high sensitivity, non-toxic and harmless. Magnetic detection method according to the type of carrier liquid into the wet and dry assay detection: detection of wet powder is suspended in the carrier liquid detection method based on detection of the dry air as the dry powder is applied to the carrier surface is detected method. When using the wet test, the black magnetic paste can be mixed with water to give a concentration suitable for a magnetic suspension, the proposed formulation at a concentration of 10-25g each black magnetic paste with 1 liter of water. Scope of magnetic paste: 1 black magnetic paste applied to the weld on the special equipment, aerospace parts and workpieces requiring high sensitivity detection. 2 black magnetic paste suitable for detecting large quantities of the workpiece, often used in conjunction with the fixed equipment. 3 black magnetic paste suitable for detecting small surface defects such as fatigue cracks, grinding cracks, hairline cracks and welding, etc. Operation points when using the magnetic cream: 1 black magnetic magnetic suspension can be formulated cream pouring method, spray method and leaching, but not using the brush method. 2 - Continuous casting method and the spray method is preferred, the black magnetic cream with liquid flow to faint, have been washed away in order to avoid the formation of magnetic marks display. 3 When the ratio of water and black magnetic paste, water breaking experiments should be conducted. 4 concentration ratio of water and black magnetic paste the recommended concentration, according to a variety of different workpiece surface, choose a different ratio of the concentration of the black magnetic cream. 5. Looking up testing and water testing should use black magnetic cream. Black non-magnetic paste applied to the wet fluorescent magnetic particle inspection, was seized when the workpiece is light, the high contrast black magnetic paste and the workpiece; If the surface is dark black magnetic cream contrast with the workpiece is not clear, contrast enhancement is recommended agents to improve the contrast of the black magnetic paste and the workpiece. Magnetic cream particle size: 10μm ≤ 80% ≤ 40μm recommendations formulated concentration: Each 10-25g black magnetic cream with 1 liter of water Contact: Sally Fax :023 -68,651,838 Mobile: 13628326704 QQ: 1739342435 E-mail: 1739342435@qq.com roughness , ultrasonic flaw detector steps video tutorial: http://i.youku.com/leeb17 Company Name: Chongqing Faribault Instrument Co., Ltd. Address: Huangshan Middle Road, Yuzhong District Hi-tech Park, the 5th Mercury South Building B1 Wing, 6th Floor Plant Factory Direct: Leeb hardness, roughness tester, ultrasonic flaw detector, ultrasonic thickness gauge, coating thickness, magnetic detectors, Oxford coating thickness (Oxford Quanguozongdai) |
Admin>>>
You are the 7360 visitor
Copyright ©2025 GuangDong ICP No. 10089450, Instrument Co., Ltd. in Chongqing, Bo All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7360 visitor
Copyright ©2025 GuangDong ICP No. 10089450, Instrument Co., Ltd. in Chongqing, Bo All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility